Heart Rhythm ; 21(5): 519-520, 2024 May.
Article in English | MEDLINE | ID: mdl-38692816
2.
Arq Bras Cardiol ; 121(4): e20230544, 2024.
Article in Portuguese, English | MEDLINE | ID: mdl-38695471

ABSTRACT

BACKGROUND: Ablation Index (AI) software has allowed better atrial fibrillation (AF) ablation results, but recurrence rates remain significant. Specific serum biomarkers have been associated with this recurrence. OBJECTIVES: To evaluate whether certain biomarkers could be used (either individually or combined) to predict arrhythmia recurrence after AI-guided AF ablation. METHODS: Prospective multicenter observational study of consecutive patients referred for AF ablation from January 2018 to March 2021. Hemoglobin, brain natriuretic peptide (BNP), C-reactive protein, high sensitivity cardiac troponin I, creatinine clearance, thyroid-stimulating hormone (TSH) and free thyroxine (FT4) were assessed for their ability to predict arrhythmia recurrence during follow-up. Statistical significance was accepted for p values of<0.05. RESULTS: A total of 593 patients were included - 412 patients with paroxysmal AF and 181 with persistent AF. After a mean follow-up of 24±6 months, overall single-procedure freedom from atrial arrhythmia was 76.4%. Individually, all biomarkers had no or only modest predictive power for recurrence. However, a TSH value >1.8 µUI/mL (HR=1.82 [95% CI, 1.89-2.80], p=0.006) was an independent predictor of arrhythmia recurrence. When assessing TSH, FT4 and BNP values in combination, each additional "abnormal" biomarker value was associated with a lower freedom from arrhythmia recurrence (87.1 % for no biomarker vs. 83.5% for one vs. 75.1% for two vs. 43.3% for three biomarkers, p<0.001). Patients with three "abnormal" biomarkers had a threefold higher risk of AF recurrence compared with no "abnormal" biomarker (HR=2.88 [95% CI, 1.39-5.17], p=0.003). CONCLUSIONS: When used in combination, abnormal TSH, FT4 and BNP values can be a useful tool for predicting arrhythmia recurrence after AI-guided AF ablation.


FUNDAMENTO: O software ablation index (AI) permitiu melhorar os resultados da ablação de fibrilação atrial (FA), mas as taxas de recorrência permanecem significativas. Biomarcadores séricos específicos têm sido associados a essa recorrência. OBJETIVOS: Avaliar se certos biomarcadores podem ser utilizados (individualmente ou combinados) para predizer a recorrência de FA pós ablação guiada pelo AI. MÉTODOS: Estudo multicêntrico, observacional, prospectivo de pacientes consecutivos, encaminhados para ablação de FA de janeiro de 2018 a março de 2021. Hemoglobina, peptídeo natriurético cerebral (BNP), proteína C reativa, troponina I ultrassensível, clearance de creatinina, Hormônio Tireoestimulante (TSH), e Tiroxina livre (T4) foram avaliados quanto à capacidade de prever a recorrência de arritmias durante o acompanhamento. Valores de p <0,05 foram aceitos como estatisticamente significativos. RESULTADOS: Um total de 593 pacientes foram incluídos ­ 412 com FA paroxística e 181 com FA persistente. Durante o seguimento médio de 24±6 meses, 76,4% não apresentaram recidiva após ablação. Individualmente, os biomarcadores demonstraram um valor preditivo baixo ou nulo para recorrência. No entanto, TSH >1,8 µUI/mL [HR=1,82 (IC95%, 1,89-2,80), p=0,006] foi um preditor independente de recorrência. Avaliando-se a combinação de TSH, FT4 e BNP, a adição de cada valor "anormal" foi associada a uma menor sobrevida livre de recorrência (87,1% se nenhum vs. 83,5% se um vs. 75,1% se dois vs. 43,3% se três biomarcadores, p<0,001). Doentes com três biomarcadores "anormais" apresentaram três vezes maior probabilidade de recorrência de FA, comparativamente aos que não apresentaram nenhum biomarcador "anormal" (HR=2,88 [IC95%, 1,39-5,17], p=0,003). CONCLUSÕES: Quando combinados, valores anormais de TSH, FT4 e BNP podem ser uma ferramenta útil para prever a recorrência de FA pós ablação guiada pelo AI.


Subject(s)
Atrial Fibrillation , Biomarkers , Catheter Ablation , Recurrence , Thyrotropin , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/blood , Biomarkers/blood , Male , Female , Prospective Studies , Middle Aged , Catheter Ablation/methods , Aged , Thyrotropin/blood , Natriuretic Peptide, Brain/blood , Predictive Value of Tests , C-Reactive Protein/analysis , Treatment Outcome , Thyroxine/blood , Risk Factors , Troponin I/blood
3.
BMJ Open ; 14(5): e079881, 2024 May 09.
Article in English | MEDLINE | ID: mdl-38724059

ABSTRACT

OBJECTIVES: Pulsed field ablation (PFA) is a promising new ablation modality for the treatment of atrial fibrillation (AF) that has recently become available in the UK National Health Service (NHS). We provide the first known economic evaluation of the technology. METHODS: A cost-comparison model was developed to compare the expected 12-month costs of treating AF using the pentaspline PFA catheter compared with cryoablation for a single hypothetical patient. Model parameters were based on a recent cost-effectiveness analysis by the National Institute for Health and Care Excellence where possible or published literature otherwise. Deterministic sensitivity, scenario and threshold analyses were conducted. RESULTS: Costs for a single patient treated with PFA were -3% (-£343) less over 12 months than those who received treatment with cryoablation. PFA was associated with 16% higher catheter costs but repeat ablation costs were over 50% less, driven by a reduction in repeat ablations required. Costs of managing complications were -£211 less in total for PFA compared with cryoablation. CONCLUSIONS: Routine adoption of PFA with the pentaspline PFA catheter looks to be as affordable for the NHS as current treatment alternative cryoablation.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cost-Benefit Analysis , Cryosurgery , State Medicine , Atrial Fibrillation/surgery , Atrial Fibrillation/economics , Atrial Fibrillation/therapy , Humans , Cryosurgery/economics , Cryosurgery/methods , United Kingdom , Catheter Ablation/economics , Catheter Ablation/methods , State Medicine/economics
4.
Zhonghua Gan Zang Bing Za Zhi ; 32(4): 332-339, 2024 Apr 20.
Article in Chinese | MEDLINE | ID: mdl-38733188

ABSTRACT

Objective: To evaluate the long-term efficacy of percutaneous microwave ablation (MWA) therapy for hepatocellular carcinoma. Methods: 2054 cases with Barcelona Clinic Liver Cancer (BCLC) stage 0~B at the Fifth Medical Center of the Chinese People's Liberation Army General Hospital from January 2006 to September 2020 were retrospectively collected. All patients were followed up for at least 2 years. The primary endpoint of overall survival and secondary endpoints (tumor-related survival, disease-free survival, and postoperative complications) of patients treated with ultrasound-guided percutaneous MWA were analyzed. Kaplan-Meier method was used for stratified survival rate analysis. Fine-and-Gray competing risk model was used to analyze overall survival. Results: A total of 5 503 HCC nodules [mean tumor diameter (2.6±1.6) cm] underwent 3 908 MWAs between January 2006 and September 2020, with a median follow-up time of 45.6 (24.0 -79.2) months.The technical effectiveness rate of 5 375 tumor nodules was 97.5%. The overall survival rates at 5, 10, and 15-years were 61.6%, 38.8%, and 27.0%, respectively. The tumor-specific survival rates were 67.1%, 47.2%, and 37.7%, respectively. The free tumor survival rates were 25.8%, 15.7%, and 9.9%, respectively. The incidence rate of severe complications was 2.8% (108/3 908). Further analysis showed that the technical effectiveness and survival rate over the passing three time periods from January 2006-2010, 2011-2015, and 2016-September 2020 were significantly increased, with P < 0.001, especially for liver cancer 3.1~5.0 cm (P < 0.001). Conclusion: Microwave ablation therapy is a safe and effective method for BCLC stage 0-B, with significantly enhanced technical efficacy and survival rate over time.


Subject(s)
Carcinoma, Hepatocellular , Liver Neoplasms , Microwaves , Humans , Liver Neoplasms/surgery , Liver Neoplasms/therapy , Carcinoma, Hepatocellular/therapy , Carcinoma, Hepatocellular/surgery , Microwaves/therapeutic use , Retrospective Studies , Survival Rate , Treatment Outcome , Disease-Free Survival , Catheter Ablation/methods , Female , Postoperative Complications/epidemiology , Male , Middle Aged
5.
Int J Mol Sci ; 25(9)2024 Apr 25.
Article in English | MEDLINE | ID: mdl-38731908

ABSTRACT

In atrial fibrillation (AF), multifactorial pathologic atrial alterations are manifested by structural and electrophysiological changes known as atrial remodeling. AF frequently develops in the context of underlying cardiac abnormalities. A critical mechanistic role played by atrial stretch is played by abnormal substrates in a number of conditions that predispose to AF, including obesity, heart failure, hypertension, and sleep apnea. The significant role of overweight and obesity in the development of AF is known; however, the differential effect of overweight, obesity, cardiovascular comorbidities, lifestyle, and other modifiable risk factors on the occurrence and recurrence of AF remains to be determined. Reverse remodeling of the atrial substrate and subsequent reduction in the AF burden by conversion into a typical sinus rhythm has been associated with weight loss through lifestyle changes or surgery. This makes it an essential pillar in the management of AF in obese patients. According to recently published research, microRNAs (miRs) may function as post-transcriptional regulators of genes involved in atrial remodeling, potentially contributing to the pathophysiology of AF. The focus of this review is on their modulation by both weight loss and catheter ablation interventions to counteract atrial remodeling in AF. Our analysis outlines the experimental and clinical evidence supporting the synergistic effects of weight loss and catheter ablation (CA) in reversing atrial electrical and structural remodeling in AF onset and in recurrent post-ablation AF by attenuating pro-thrombotic, pro-inflammatory, pro-fibrotic, arrhythmogenic, and male-sex-associated hypertrophic remodeling pathways. Furthermore, we discuss the promising role of miRs with prognostic potential as predictive biomarkers in guiding approaches to AF recurrence prevention.


Subject(s)
Atrial Fibrillation , Biomarkers , Catheter Ablation , MicroRNAs , Weight Loss , Atrial Fibrillation/metabolism , Atrial Fibrillation/genetics , Atrial Fibrillation/etiology , Humans , MicroRNAs/genetics , MicroRNAs/metabolism , Catheter Ablation/methods , Recurrence , Atrial Remodeling , Animals , Obesity/metabolism , Obesity/complications
6.
Med Sci Monit ; 30: e943526, 2024 May 12.
Article in English | MEDLINE | ID: mdl-38734884

ABSTRACT

BACKGROUND A significant number of atrial fibrillation (AF) recurrences occur after initial ablation, often due to pulmonary vein reconnections or triggers from non-pulmonary veins. MATERIAL AND METHODS Patients with paroxysmal AF who underwent radiofrequency catheter ablation for the first time were enrolled. Base on propensity score matching (1: 1 matching), 118 patients were selected for an optimized workflow for the radiofrequency catheter ablation of paroxysmal AF (OWCA) group and a conventional group. Comparative analysis of the acute and 12-month clinical outcomes was conducted. Moreover, an artificial intelligence analytics platform was used to evaluate the quality of pulmonary vein isolation (PVI) circles. RESULTS PVI was successfully achieved in all patients. Incidence of first-pass isolation of bilateral PVI circles was higher (P=0.009) and acute pulmonary vein reconnections was lower (P=0.027) in the OWCA group than conventional group. The OWCA group displayed a significant reduction in the number of fractured points (P<0.001), stacked points (P=0.003), and a greater proportion of cases in which the radiofrequency index achieved the target value (P=0.003). Additionally, the contact force consistently met the force over time criteria (P<0.001) for bilateral PVI circles in the OWCA group, accompanied by a shorter operation time (P=0.017). During the 12-month follow-up period, the OWCA group exhibited a higher atrial arrhythmia-free survival rate following the initial ablation procedure than did the conventional group. CONCLUSIONS The optimized workflow for radiofrequency catheter ablation of paroxysmal AF could play a crucial role in creating higher quality PVI circles. This improvement is reflected in a significantly elevated 12-month atrial arrhythmia-free survival rate.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Workflow , Humans , Atrial Fibrillation/surgery , Catheter Ablation/methods , Female , Male , Middle Aged , Treatment Outcome , Pulmonary Veins/surgery , Aged , Propensity Score , Recurrence
8.
Rev Assoc Med Bras (1992) ; 70(4): e2023D704, 2024.
Article in English | MEDLINE | ID: mdl-38747880

ABSTRACT

The Guidelines Project, which is an initiative of the Brazilian Medical Association, aims to combine information from the medical field to standardize how to conduct and assist in the reasoning and decision-making of doctors. The information provided by this project must be critically evaluated by the physician responsible for the conduct that will be adopted, depending on the conditions and the clinical condition of each patient.


Subject(s)
Hypertension , Kidney , Humans , Hypertension/surgery , Kidney/innervation , Treatment Outcome , Sympathectomy/methods , Catheter Ablation/methods
10.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38696675

ABSTRACT

AIMS: Contact force (CF)-sensing radiofrequency (RF) catheters with an ablation index have shown reproducible outcomes for the treatment of atrial fibrillation (AF) in large multicentre studies. A dual-energy (DE) focal CF catheter to deliver RF and unipolar/biphasic pulsed field ablation (PFA), integrated with a three-dimensional (3D) mapping system, can provide operators with additional flexibility. The SmartfIRE study assessed the safety and efficacy of this novel technology for the treatment of drug-refractory, symptomatic paroxysmal AF. Results at 3 months post-ablation are presented here. METHODS AND RESULTS: Pulmonary vein isolation (PVI) was performed using a DE focal, irrigated CF-sensing catheter with the recommendation of PFA at posterior/inferior and RF ablation at the anterior/ridge/carina segments. Irrespective of energy, a tag size of 3 mm; an inter-tag distance ≤6 mm; a target index of 550 for anterior, roof, ridge, and carina; and a target index of 400 for posterior and inferior were recommended. Cavotricuspid isthmus ablation was permitted in patients with documented typical atrial flutter. The primary effectiveness endpoint was acute procedural success. The primary safety endpoint was the rate of primary adverse events (PAEs) within 7 days of the procedure. A prespecified patient subset underwent oesophageal endoscopy (EE; 72 h post-procedure), neurological assessment (NA; pre-procedure and discharge), and cardiac computed tomography (CT)/magnetic resonance angiogram (MRA) imaging (pre-procedure and 3 months post-procedure) for additional safety evaluation, and a mandatory remapping procedure (Day 75 ± 15) for PVI durability assessment. Of 149 patients enrolled between February and June 2023, 140 had the study catheter inserted (safety analysis set) and 137 had ablation energy delivered (per-protocol analysis set). The median (Q1/Q3) total procedure and fluoroscopy times were 108.0 (91.0/126.0) and 4.2 (2.3/7.7) min (n = 137). The acute procedural success rate was 100%. First-pass isolation was achieved in 89.1% of patients and 96.8% of veins. Cavotricuspid isthmus ablations were successfully performed in 12 patients [pulsed field (PF) only: 6, RF only: 5, and RF/PF: 1]. The PAE rate was 4.4% [6/137 patients; 2 pulmonary vein (PV) stenoses, 2 cardiac tamponades/perforations, 1 stroke, and 1 pericarditis]. No coronary artery spasm was reported. No oesophageal lesion was seen in the EE subset (0/31, 0%). In the NA subset (n = 30), microemboli lesions were identified in 2 patients (2/30, 6.7%), both of which were resolved at follow-up; only 1 was symptomatic (silent cerebral lesion, 3.3%). In the CT/MRA subset (n = 30), severe PV narrowing (of >70%) was detected in 2 patients (2/30, 6.7%; vein level 2/128, 1.6%), of whom 1 underwent dilatation and stenting and 1 was asymptomatic; both were associated with high index values and a small inter-tag distance. In the PV durability subset (n = 30), 100/115 treated PVs (87%) were durably isolated and 18/30 patients (60.0%) had all PVs durably isolated. CONCLUSION: A DE focal CF catheter with 3D mapping integration showed a 100% acute success rate with an acceptable safety profile in the treatment of paroxysmal AF. Prespecified 3-month remapping showed notable PVI durability. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT05752487.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Male , Female , Catheter Ablation/methods , Catheter Ablation/instrumentation , Middle Aged , Treatment Outcome , Aged , Imaging, Three-Dimensional , Cardiac Catheters , Time Factors , Equipment Design , Prospective Studies , Recurrence
11.
Radiol Technol ; 95(5): 321-326, 2024 May.
Article in English | MEDLINE | ID: mdl-38719553

ABSTRACT

BACKGROUND: This case details a 44-year-old man with end-stage ischemic cardiomyopathy with refractory ventricular tachycardia (VT). The patient has a single-chamber implantable cardioverter-defibrillator, has had 2 VT ablations, and uses medication to manage his VT. Despite these interventions, he continued to have episodes of VT. The patient underwent stereotactic body radiation therapy (SBRT) to help reduce the burden of his VT. The patient received a dose of 25 Gy to his right inferior lateral region of the heart and a dose of 15 Gy to the inferior portion of the heart closer to the stomach. The patient followed up 1 month later and reported that his energy levels improved and that no arrhythmias had occurred since his SBRT treatment. DISCUSSION: The options for treating end-stage VT are limited. However, a treatment option using SBRT has been introduced to reduce the VT burden in patients. Cardiac SBRT is a noninvasive outpatient procedure that, while still awaiting U.S. Food and Drug Administration approval, reduces arrhythmia episodes and offers favorable short-term benefits for patients who have not responded to traditional treatment modalities. CONCLUSION: Cardiac SBRT is a novel treatment for VT in patients where standard treatments have failed. This case study demonstrates that SBRT effectively reduced arrhythmias in a patient with VT. The long-term clinical outcomes are not known, but the opportunity SBRT offers for treatment-refractory patients is favorable and should be considered.


Subject(s)
Radiosurgery , Tachycardia, Ventricular , Humans , Male , Tachycardia, Ventricular/surgery , Adult , Radiosurgery/methods , Defibrillators, Implantable , Catheter Ablation/methods
12.
J Vis Exp ; (206)2024 Apr 19.
Article in English | MEDLINE | ID: mdl-38709062

ABSTRACT

Radiofrequency (RF) ablation to perform pulmonary vein isolation (PVI) for the treatment of atrial fibrillation involves some risk to collateral structures, including the esophagus. Proactive esophageal cooling using a dedicated device has been granted marketing authorization by the Food and Drug Administration (FDA) to reduce the risk of ablation-related esophageal injury due to RF cardiac ablation procedures, and more recent data also suggest that esophageal cooling may contribute to improved long-term efficacy of treatment. A mechanistic underpinning explaining these findings exists through the quantification of lesion placement contiguity defined as the Continuity Index (CI). Kautzner et al. quantified the CI by the order of lesion placement, such that whenever a lesion is placed non-adjacent to the prior lesion, the CI is incremented by the number of segments the catheter tip has moved over. To facilitate real-time calculation of the CI and encourage further adoption of this instrument, we propose a modification in which the placement of non-adjacent lesions increments the CI by only one unit, avoiding the need to count potentially nebulous markers of atrial segmentation. The objective of this protocol is to describe the methods of calculating the CI both prospectively during real-time PVI cases and retrospectively using recorded case data. A comparison of the results obtained between cases that utilized proactive esophageal cooling and cases that used luminal esophageal temperature (LET) monitoring is then provided.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Esophagus , Atrial Fibrillation/surgery , Esophagus/surgery , Humans , Catheter Ablation/methods , Catheter Ablation/instrumentation , Pulmonary Veins/surgery
13.
Heart Rhythm ; 21(5): 705-706, 2024 May.
Article in English | MEDLINE | ID: mdl-38692817
14.
Clin Imaging ; 110: 110170, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38696998

ABSTRACT

INTRODUCTION: In patients with atrial fibrillation (AF), up to one third have recurrence after a first catheter ablation (CA). Epicardial adipose tissue (EAT) has been considered to be closely related to AF, with a potential role in its recurrence. We aimed to evaluate the association between the volume of EAT measured by cardiac computed tomography (CT) and AF recurrence after CA. METHODS: Consecutive AF patients underwent a standardized cardiac CT protocol for quantification of EAT, thoracic adipose volume (TAV) and left atrium (LA) volume before CA. An appropriate cut-off of EAT was determined and risk recurrence was estimated. RESULTS: 305 patients (63.6 % male, mean age 57.5 years, 28.2 % persistent AF) were followed for 24 months; 23 % had AF recurrence at 2-year mark, which was associated with higher EAT (p = 0.037) and LAV (p < 0.001). Persistent AF was associated with higher EAT volumes (p = 0.010), TAV (p = 0.003) and LA volumes (p < 0.001). EAT was predictive of AF recurrence (p = 0.044). After determining a cut-off of 92 cm3, survival analysis revealed that EAT volumes > 92 cm3 showed higher recurrence rates at earlier time points after the index ablation procedure (p = 0.006), with a HR of 1.95 (p = 0.008) of AF recurrence at 2-year. After multivariate adjustment, EAT > 92 cm3 remained predictive of AF recurrence (p = 0.028). CONCLUSION: The volume of EAT measured by cardiac CT can predict recurrence of AF after ablation, with a volume above 92 cm3 yielding almost twice the risk of arrhythmia recurrence in the first two years following CA. Higher EAT and TAV are also associated with persistent AF.


Subject(s)
Adipose Tissue , Atrial Fibrillation , Catheter Ablation , Pericardium , Recurrence , Tomography, X-Ray Computed , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/diagnostic imaging , Male , Female , Adipose Tissue/diagnostic imaging , Middle Aged , Catheter Ablation/methods , Pericardium/diagnostic imaging , Pericardium/pathology , Tomography, X-Ray Computed/methods , Predictive Value of Tests , Aged , Treatment Outcome , Epicardial Adipose Tissue
15.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38647070

ABSTRACT

AIMS: Simplified ablation technologies for pulmonary vein isolation (PVI) are increasingly performed worldwide. One of the most common complications following PVI are vascular access-related complications. Lately, venous closure systems (VCSs) were introduced into clinical practice, aiming to reduce the time of bed rest, to increase the patients' comfort, and to reduce vascular access-related complications. The aim of the present study is to compare the safety and efficacy of using a VCS to achieve haemostasis following single-shot PVI to the actual standard of care [figure-of-eight suture and manual compression (MC)]. METHODS AND RESULTS: This is a prospective, multicentre, randomized, controlled, open-label trial performed at three German centres. Patients were randomized 1:1 to undergo haemostasis either by means of VCS (VCS group) or of a figure-of-eight suture and MC (F8 group). The primary efficacy endpoint was the time to ambulation, while the primary safety endpoint was the incidence of major periprocedural adverse events until hospital discharge. A total of 125 patients were randomized. The baseline characteristics were similar between the groups. The VCS group showed a shorter time to ambulation [109.0 (82.0, 160.0) vs. 269.0 (243.8, 340.5) min; P < 0.001], shorter time to haemostasis [1 (1, 2) vs. 5 (2, 10) min; P < 0.001], and shorter time to discharge eligibility [270 (270, 270) vs. 340 (300, 458) min; P < 0.001]. No major vascular access-related complication was reported in either group. A trend towards a lower incidence of minor vascular access-related complications on the day of procedure was observed in the VCS group [7 (11.1%) vs. 15 (24.2%); P = 0.063] as compared to the control group. CONCLUSION: Following AF ablation, the use of a VCS results in a significantly shorter time to ambulation, time to haemostasis, and time to discharge eligibility. No major vascular access-related complications were identified. The use of MC and a figure-of-eight suture showed a trend towards a higher incidence of minor vascular access-related complications.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Suture Techniques , Humans , Atrial Fibrillation/surgery , Female , Male , Middle Aged , Catheter Ablation/adverse effects , Catheter Ablation/methods , Prospective Studies , Pulmonary Veins/surgery , Suture Techniques/adverse effects , Aged , Treatment Outcome , Germany , Time Factors , Vascular Closure Devices , Early Ambulation , Hemostatic Techniques/instrumentation
17.
Int J Cardiol ; 406: 132025, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38583595

ABSTRACT

INTRODUCTION: In patients with paroxysmal atrial fibrillation, pulsed-field ablation has been developed as an alternative to thermal ablation. Three devices are currently available: Farawave by Boston, PulseSelect by Medtronic, and Varipulse by Johnson. In the present report, we studied the outcomes at 12 months of these three devices using indirect comparisons. METHODS: A standard PubMed search was conducted that identified all studies evaluating these devices in patients with paroxysmal atrial fibrillation. The endpoint was freedom from arrhythmia recurrence. Kaplan-Meier curves were subjected to the IPDfromKM method that generated reconstructed patients. Standard time-to-event statistical testss (including heterogeneity assessment) were performed. RESULTS: Our analysis included 9 studies (8 single-arm and 1 randomized trial based on Farawave for a total of 1916 patients). A significant heterogeneity was found across the trials using Farawave because the outcomes found in the single-arm trials were better than those found in the randomized trial. Farawave (according exclusively to the results of the randomized trial), PulseSelect, and Varipulse showed a similar time-course of their respective outcomes with no significant difference. The single-arm trials using Farawave showed better outcomes than the randomized trial using Farawave and the pivotal trials using PulseSelect and Varipulse. DISCUSSION: Our study provided an updated overview of all the studies that have so far used pulsed-fileld ablation in patients with paroxysmal atrial fibrillation.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Randomized Controlled Trials as Topic , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Humans , Catheter Ablation/methods , Catheter Ablation/instrumentation , Randomized Controlled Trials as Topic/methods , Treatment Outcome
18.
J Am Heart Assoc ; 13(9): e034004, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38639381

ABSTRACT

BACKGROUND: An epicardial connection (EC) through the intercaval bundle (EC-ICB) between the right pulmonary vein (RPV) and right atrium (RA) is one of the reasons for the need for carina ablation for PV isolation and may reduce the acute and chronic success of PV isolation. We evaluated the intra-atrial activation sequence during RPV pacing after failure of ipsilateral RPV isolation and sought to identify specific conduction patterns in the presence of EC-ICB. METHODS AND RESULTS: This study included 223 consecutive patients who underwent initial catheter ablation of atrial fibrillation. If the RPV was not isolated using circumferential ablation or reconnected during the waiting period, an exit map was created during mid-RPV carina pacing. If the earliest site on the exit map was the RA, the patient was classified into the EC-ICB group. The exit map, intra-atrial activation sequence, and RPV-high RA time were evaluated. First-pass isolation of the RPV was not achieved in 36 patients (16.1%), and 22 patients (9.9%) showed reconnection. Twelve and 28 patients were classified into the EC-ICB and non-EC-ICB groups, respectively, after excluding those with multiple ablation lesion sets or incomplete mapping. The intra-atrial activation sequence showed different patterns between the 2 groups. The RPV-high RA time was significantly shorter in the EC-ICB than in the non-EC-ICB group (69.2±15.2 versus 148.6±51.2 ms; P<0.001), and RPV-high RA time<89.0 ms was highly predictive of the existence of an EC-ICB (sensitivity, 91.7%; specificity, 89.3%). CONCLUSIONS: An EC-ICB can be effectively detected by intra-atrial sequencing during RPV pacing, and an RPV-high RA time of <89.0 ms was highly predictive.


Subject(s)
Atrial Fibrillation , Cardiac Pacing, Artificial , Catheter Ablation , Heart Atria , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Pulmonary Veins/physiopathology , Female , Male , Catheter Ablation/methods , Middle Aged , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Cardiac Pacing, Artificial/methods , Aged , Heart Atria/physiopathology , Heart Atria/surgery , Treatment Outcome , Retrospective Studies , Pericardium/surgery , Pericardium/physiopathology , Heart Conduction System/physiopathology , Action Potentials , Electrophysiologic Techniques, Cardiac , Heart Rate/physiology
19.
Sci Rep ; 14(1): 8974, 2024 04 18.
Article in English | MEDLINE | ID: mdl-38637577

ABSTRACT

Fully CMR-guided electrophysiological interventions (EP-CMR) have recently been introduced but data on the optimal CMR imaging protocol are scarce. This study determined the clinical utility of 3D non-selective whole heart steady-state free precession imaging using compressed SENSE (nsWHcs) for automatic segmentation of cardiac cavities as the basis for targeted catheter navigation during EP-CMR cavo-tricuspid isthmus ablation. Fourty-two consecutive patients with isthmus-dependent right atrial flutter underwent EP-CMR radiofrequency ablations. nsWHcs succeeded in all patients (nominal scan duration, 98 ± 10 s); automatic segmentation/generation of surface meshes of right-sided cavities exhibited short computation times (16 ± 3 s) with correct delineation of right atrium, right ventricle, tricuspid annulus and coronary sinus ostium in 100%, 100%, 100% and 95%, respectively. Point-by-point ablation adhered to the predefined isthmus line in 62% of patients (26/42); activation mapping confirmed complete bidirectional isthmus block (conduction time difference, 136 ± 28 ms). nsWHcs ensured automatic and reliable 3D segmentation of targeted endoluminal cavities, multiplanar reformatting and image fusion (e.g. activation time measurements) and represented the basis for precise real-time active catheter navigation during EP-CMR ablations of isthmus-dependent right atrial flutter. Hence, nsWHcs can be considered a key component in order to advance EP-CMR towards the ultimate goal of targeted substrate-based ablation procedures.


Subject(s)
Atrial Flutter , Catheter Ablation , Humans , Atrial Flutter/diagnostic imaging , Atrial Flutter/surgery , Surgical Mesh , Catheter Ablation/methods , Heart Atria/diagnostic imaging , Heart Atria/surgery , Arrhythmias, Cardiac , Treatment Outcome
20.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38584394

ABSTRACT

AIMS: Catheter ablation (CA) of ventricular tachycardia (VT) has become an important tool to improve clinical outcomes in patients with appropriate transvenous implantable cardioverter defibrillator (ICD) shocks. The aim of our analysis was to test whether VT ablation (VTA) impacts long-term clinical outcomes even in subcutaneous ICD (S-ICD) carriers. METHODS AND RESULTS: International Subcutaneous Implantable Cardioverter Defibrillator (iSUSI) registry patients who experienced either an ICD shock or a hospitalization for monomorphic VT were included in this analysis. Based on an eventual VTA after the index event, patients were divided into VTA+ vs. VTA- cohorts. Primary outcome of the study was the occurrence of a combination of device-related appropriate shocks, monomorphic VTs, and cardiovascular mortality. Secondary outcomes were addressed individually. Among n = 1661 iSUSI patients, n = 211 were included: n = 177 experiencing ICD shocks and n = 34 hospitalized for VT. No significant differences in baseline characteristics were observed. Both the crude and the yearly event rate of the primary outcome (5/59 and 3.8% yearly event rate VTA+ vs. 41/152 and 16.4% yearly event rate in the VTA-; log-rank: P value = 0.0013) and the cardiovascular mortality (1/59 and 0.7% yearly event rate VTA+ vs. 13/152 and 4.7% yearly event rate VTA-; log-rank P = 0.043) were significantly lower in the VTA + cohort. At multivariate analysis, VTA was the only variable remaining associated with a lower incidence of the primary outcome [adjusted hazard ratio 0.262 (0.100-0.681), P = 0.006]. CONCLUSION: In a real-world registry of S-ICD carriers, the combined study endpoint of arrhythmic events and cardiovascular mortality was lower in the patient cohort undergoing VTA at long-term follow-up. CLINICALTRIALS.GOV IDENTIFIER: NCT0473876.


Subject(s)
Catheter Ablation , Defibrillators, Implantable , Tachycardia, Ventricular , Humans , Arrhythmias, Cardiac/etiology , Catheter Ablation/adverse effects , Catheter Ablation/methods , Electric Countershock/adverse effects , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Treatment Outcome